Servicios
Evaluación de calidad del aire interior (IAQ)
Investigue las condiciones interiores, los contaminantes del aire y sus posibles fuentes.
Hablemos de su proyectoHablemos de su proyecto
CONOZCA SUS OPCIONES
Conozca su evaluación en detalle.
Indoor air quality can influence occupant comfort and may contribute to potential exposure to airborne contaminants and other environmental hazards. BNF's IAQ assessments evaluate temperature, relative humidity, carbon dioxide, particulate matter, VOCs, biological aerosols, odors, moisture conditions, and other relevant indoor environmental parameters, as appropriate to the assessment scope. Targeted measurements and sampling provide objective data to help identify potential environmental sources and guide corrective measures, with consideration of applicable OSHA requirements, EPA guidance, ASHRAE standards, state and local requirements, and other recognized indoor environmental criteria, as applicable.

Alcance de la evaluación
Lo que su evaluación
puede incluir.
- CO₂ assessment as an indicator of ventilation conditions
- CO monitoring for potential combustion sources
- TVOC assessment
- TMVOC assessment
- Targeted VOC analysis
- Formaldehyde testing
- PM₂.₅ and PM₁₀ monitoring
- Temperature and relative humidity
- Fungal and bacterial bioaerosol assessment
- Odor and source investigation
- Targeted mycotoxin or specialized chemical testing where indicated
QUÉ ESPERAR
Desde su primera pregunta
hasta su informe final.
- 01
Alcance y presupuesto
Tell us the property address, year built, current and historical property use, building type, occupant concerns, suspected sources, and intended use of the assessment. BNF establishes the appropriate assessment parameters, measurements, sampling strategy, and evaluation criteria.
- 02
BNF IAQ Assessment
BNF professionals evaluate indoor environmental conditions using appropriate instruments and methods, including temperature, relative humidity, carbon dioxide, particulate matter, VOCs, biological aerosols, odors, moisture conditions, and other relevant parameters, as applicable.
- 03
Sampling & Analysis
Where laboratory testing is warranted, environmental samples are collected using appropriate methods and submitted to an appropriately accredited laboratory. Instrument measurements and field observations are documented as part of the assessment.
- 04
Revisión por CIH e informe
BNF's Certified Industrial Hygienist (CIH) reviews and interprets applicable environmental data, where appropriate. The report documents observed conditions, analytical results, applicable criteria, and recommendations for further evaluation or corrective measures.
Cargando informes de muestra…
UN COMIENZO MÁS CLARO
Preguntas y respuestas
¿Qué diferencia hay entre evaluar la calidad del aire interior y el moho?
La evaluación de IAQ abarca una gama más amplia de condiciones ambientales interiores y posibles fuentes de exposición. La evaluación de moho se centra en el crecimiento fúngico, la humedad, los materiales dañados por agua y, cuando corresponde, el muestreo de hongos y el análisis de laboratorio.
¿Qué indica un nivel elevado de CO₂ en interiores?
Las mediciones de CO₂ interior pueden aportar información sobre ventilación y condiciones relacionadas con la ocupación, y deben interpretarse junto con las condiciones del edificio y los criterios de ventilación aplicables.